C# library for the usbtemp.com USB thermometer and DS9097E compatible 1-wire adapters with one DS18B20 digital probe attached. It is the C# counterpart of the utmp-cli command line utility.
| Folder | Contents |
|---|---|
usbtemp |
Class library usbtemp.dll with the Thermometer class (namespace usbtemp), source in usbtemp/usbtemp.cs |
usbtemp-demo |
Console application (.NET Framework 4.0) that reads the probe using the library |
The library targets net40 (.NET Framework 4.0 and newer) and netstandard2.0 (.NET Framework 4.6.1+, .NET Core, .NET 5 and newer on Windows, Linux and macOS).
void Open(string port); // open serial port, e.g. "COM3" or "/dev/ttyUSB0"
void Close(); // close serial port; safe to call if Open() failed
byte[] Rom(); // probe serial number (8 bytes)
void Measure(); // start temperature conversion
float Acquire(); // read result of the last conversion, in degrees Celsius
float Temperature(); // Measure(), wait 800 ms, Acquire()
void SetPrecision(int bits); // set resolution 9..12 bits, saved to probe EEPROM
int GetPrecision(); // current resolution, 9..12 bits
Thermometer.MinPrecision and Thermometer.MaxPrecision hold the allowed resolution range.
Use Measure() and Acquire() instead of Temperature() to do other work during the conversion or to wait less at lower resolution:
| Resolution | Step | Conversion time |
|---|---|---|
| 9 bits | 0.5 °C | 94 ms |
| 10 bits | 0.25 °C | 188 ms |
| 11 bits | 0.125 °C | 375 ms |
| 12 bits | 0.0625 °C | 750 ms |
Errors:
Probe and bus errors throw ThermometerException, with the same messages as the Node.js and Python libraries:
| Message | Cause |
|---|---|
Device is not connected |
Open() was not called or the port is closed |
Read timeout |
the adapter does not answer within 500 ms |
No device present |
no probe is connected |
Short circuit |
the 1-wire bus is shorted |
Presence error: 0x.. |
unexpected response to the bus reset |
Invalid response |
a byte sent to the probe was not echoed back correctly |
CRC error |
the data read from the probe is corrupted |
Invalid device |
the probe is not a DS18B20 |
SetPrecision() throws ArgumentOutOfRangeException for a value outside 9..12.
Open() and writes throw the exceptions of System.IO.Ports.SerialPort (IOException, UnauthorizedAccessException, TimeoutException) when the serial port does not exist, is in use or cannot be accessed.
Example:
var thermometer = new usbtemp.Thermometer();
try
{
thermometer.Open("COM3");
Console.WriteLine(BitConverter.ToString(thermometer.Rom()));
Console.WriteLine($"{thermometer.Temperature():0.00} C");
}
finally
{
thermometer.Close();
}Open usbtemp-sharp.sln in Visual Studio 2017 or newer, or use the .NET SDK (Windows, Linux or macOS):
dotnet build # library and demo
dotnet pack usbtemp -c Release # NuGet package of the library
The code is limited to C# 7.0, the default language version of Visual Studio 2017.
The demo is a .NET Framework 4.0 application: it runs on Windows, and on Linux or macOS with Mono (mono usbtemp-demo.exe /dev/ttyUSB0).
usbtemp-demo <serial port>
Example output:
Serial: 28FF6A2B71160398
Precision: 12 bits
Temperature: 22.62 C
Exit code is 0 on success, 1 on a port or probe error and 2 on invalid arguments. When started by double-click on Windows, it waits for a key press before closing the window.
On Linux the user needs read/write access to the serial port, usually by being a member of the dialout group.
MIT, see LICENSE.md.